← Technology, Science & Infrastructure ▣ Distilled locally

Emerson adds magnetic flow sensor for data center cooling

By Puja Mitra
October 28, 2026  ·  Engineering.com ↗
Emerson adds magnetic flow sensor for data center cooling

Emerson has introduced the Rosemount 8795 Magnetic Flow Sensor for data center hydronic cooling applications. The flow sensor is intended to provide flow measurements for data center systems and to support specification, installation and commissioning.

The sensor can use Emerson software for short-run installations, which is intended to support flow measurement when straight-pipe requirements cannot be met in space-constrained installations. According to Emerson, the setup can provide 0.5% accuracy at zero diameters of pipe run based on upstream disturbance and distance from the electrodes when the sensor is paired with compatible Rosemount Magnetic Flow Transmitters. Emerson says this capability is available through software rather than by using a special sensor design.

For installations with upstream and downstream straight pipe runs of 5U/2D or more, the sensor can be paired with compatible Rosemount transmitters to provide flow measurement with 0.2% ± 2 mm/s accuracy for monitoring and control of cooling loops. Compatible Rosemount transmitters also provide diagnostics and verification functions that can be used during commissioning and operation.

The sensor is intended for chilled water and water-glycol cooling loops and is available for common data center line sizes from 2 to 18 inches. It provides 0.1% repeatability and is designed to send data to building management systems and data center infrastructure management systems for calculations such as WUE, CUE and PUE. Its PTFE liner and stainless-steel electrodes are intended for use in primary cooling loops and closed-loop cooling systems.

The flow sensor includes no moving parts, a 5µS/cm minimum conductivity requirement, dual 4-20mA and Modbus output, AC or DC power options, and support for integral or remote transmitter mounting. It also includes Short Run Installation software. Emerson says these features are intended to support standardization across hydronic applications at data center sites.

The Rosemount 8795 adds software functions and ordering options to Emerson’s magnetic flow meter portfolio for data center applications.

For more information, visit emerson.com.

Originally published by Engineering.com ↗ · rebuilt here from its own full-text RSS feed · all rights remain with the publisher, please read and support them there.